Site Map |
 |
Bob® SC12 Series
Gas Connectors |
 |
|
| 1/2" OD (3/8" ID) Poly Coated Stainless Steel |
|

|
 CSA Listed for USA and Canada |
 |
- For Indoor and Outdoor Installations
- High Chrome, Bright Annealed, Type 304 Austenitic Stainless Steel Tubing
- Yellow Chromate Finish 12L14 Grade Steel Nuts & End Fittings
- High Tensile Strength Stainless Steel for Greater Flexibility
- Advanced "Safety Yellow" Polymer Coating
- "No Neck" Design for Increased Safety
- Available with Ball Type Gas Valves and with End Fittings Only
- S, SC Series TechSpecs
|
| Bob® SC12B Series Dryer-Water Heater-Furnace Connectors |
- 1/2" FIP x 1/2" FIP Connections
- 1/2" OD (3/8" ID) Corrugated Tubing with 1/2" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
|
1/2" FIP 1/2" FIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC1212B |
12" |
122,400 |
CSSD55-12 |
25 |
19 |
| SC1218B |
18" |
111,720 |
CSSD55-18 |
25 |
21 |
| SC1224B |
24" |
102,000 |
CSSD55-24 |
25 |
25 |
| SC1230B |
30" |
93,939 |
CSSD55-30 |
25 |
28 |
| SC1236B |
36" |
87,715 |
CSSD55-36 |
25 |
31 |
| SC1248B |
48" |
77,000 |
CSSD55-48 |
25 |
37 |
| SC1260B |
60" |
65,474 |
CSSD55-60 |
12 |
22 |
| SC1272B |
72" |
59,000 |
CSSD55-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC12C Series Dryer-Water Heater-Furnace Connectors |
- 1/2" FIP x 1/2" MIP Connections
- 1/2" OD (3/8" ID) Corrugated Tubing with 1/2" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- 1/2" MIP Connection Tapped 3/8" FIP
|
1/2" FIP 1/2" MIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC1212C |
12" |
122,400 |
CSSD54-12 |
25 |
19 |
| SC1218C |
18" |
111,720 |
CSSD54-18 |
25 |
21 |
| SC1224C |
24" |
102,000 |
CSSD54-24 |
25 |
25 |
| SC1230C |
30" |
93,939 |
CSSD54-30 |
25 |
28 |
| SC1236C |
36" |
87,715 |
CSSD54-36 |
25 |
31 |
| SC1248C |
48" |
77,000 |
CSSD54-48 |
25 |
37 |
| SC1260C |
60" |
65,474 |
CSSD54-60 |
12 |
22 |
| SC1272C |
72" |
59,000 |
CSSD54-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC12D Series Dryer-Water Heater-Furnace Connectors |
- 1/2" MIP x 1/2" MIP Connections
- 1/2" OD (3/8" ID) Corrugated Tubing with 1/2" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- 1/2" MIP Connections Tapped 3/8" FIP
|
1/2" MIP 1/2" MIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC1212D |
12" |
122,400 |
CSSD44-12 |
25 |
19 |
| SC1218D |
18" |
111,720 |
CSSD44-18 |
25 |
21 |
| SC1224D |
24" |
102,000 |
CSSD44-24 |
25 |
25 |
| SC1230D |
30" |
93,939 |
CSSD44-30 |
25 |
28 |
| SC1236D |
36" |
87,715 |
CSSD44-36 |
25 |
31 |
| SC1248D |
48" |
77,000 |
CSSD44-48 |
25 |
37 |
| SC1260D |
60" |
65,474 |
CSSD44-60 |
12 |
22 |
| SC1272D |
72" |
59,000 |
CSSD44-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC12E Series Dryer-Water Heater-Furnace Connectors |
- 1/2" FIP x 3/8" MIP Connections
- 1/2" OD (3/8" ID) Corrugated Tubing with 1/2" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- 3/8" MIP Connection Tapped 1/4" FIP
- Non-Stock
|
1/2" FIP 3/8" MIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC1212E |
12" |
122,400 |
CSSD57-12 |
25 |
19 |
| SC1218E |
18" |
111,720 |
CSSD57-18 |
25 |
21 |
| SC1224E |
24" |
102,000 |
CSSD57-24 |
25 |
25 |
| SC1230E |
30" |
93,939 |
CSSD57-30 |
25 |
28 |
| SC1236E |
36" |
87,715 |
CSSD57-36 |
25 |
31 |
| SC1248E |
48" |
77,000 |
CSSD57-48 |
25 |
37 |
| SC1260E |
60" |
65,474 |
CSSD57-60 |
12 |
22 |
| SC1272E |
72" |
59,000 |
CSSD57-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC12V1 Series Dryer-Water Heater-Furnace Connectors |
- 1/2" MIP x 1/2" FIP Straight 1/4 Turn Ball Valve Connections
- 1/2" OD (3/8" ID) Corrugated Tubing with 1/2" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- 1/2" MIP Connection Tapped 3/8" FIP
|
1/2" MIP 1/2" FIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC1212V1 |
12" |
122,400 |
CSSD4K-12 |
25 |
31 |
| SC1218V1 |
18" |
111,720 |
CSSD4K-18 |
25 |
33 |
| SC1224V1 |
24" |
102,000 |
CSSD4K-24 |
25 |
37 |
| SC1230V1 |
30" |
93,939 |
CSSD4K-30 |
25 |
40 |
| SC1236V1 |
36" |
87,715 |
CSSD4K-36 |
25 |
43 |
| SC1248V1 |
48" |
77,000 |
CSSD4K-48 |
25 |
49 |
| SC1260V1 |
60" |
65,474 |
CSSD4K-60 |
12 |
26 |
| SC1272V1 |
72" |
59,000 |
CSSD4K-72 |
12 |
31 |