Site Map |
 |
Bob® SC78 Series
Gas Connectors |
 |
|
| 7/8" OD (1/2" ID) Poly Coated Stainless Steel |
|

|
 CSA Listed for USA and Canada |
 |
- For Indoor and Outdoor Installations
- High Chrome, Bright Annealed, Type 304 Austenitic Stainless Steel Tubing
- Yellow Chromate Finish 12L14 Grade Steel Nuts & End Fittings
- High Tensile Strength Stainless Steel for Greater Flexibility
- Advanced "Safety Yellow" Polymer Coating
- "No Neck" Design for Increased Safety
- Available with Ball Type Gas Valves and with End Fittings Only
- S, SC Series TechSpecs
|
| Bob® SC78B Series Range Connectors |
- 3/4" FIP x 3/4" FIP Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
|
3/4" FIP 3/4" FIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812B |
12" |
196,800 |
CSSC22-12 |
25 |
19 |
| SC7818B |
18" |
179,525 |
CSSC22-18 |
25 |
21 |
| SC7824B |
24" |
164,000 |
CSSC22-24 |
25 |
25 |
| SC7830B |
30" |
151,591 |
CSSC22-30 |
25 |
28 |
| SC7836B |
36" |
141,841 |
CSSC22-36 |
25 |
31 |
| SC7848B |
48" |
125,000 |
CSSC22-48 |
25 |
37 |
| SC7860B |
60" |
112,904 |
CSSC22-60 |
12 |
22 |
| SC7872B |
72" |
106,100 |
CSSC22-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC78C Series Range Connectors |
- 3/4" FIP x 3/4" MIP Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- 3/4" MIP Connection Tapped 1/2" FIP
|
3/4" FIP 3/4" MIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812C |
12" |
196,800 |
CSSC21-12 |
25 |
19 |
| SC7818C |
18" |
179,525 |
CSSC21-18 |
25 |
21 |
| SC7824C |
24" |
164,000 |
CSSC21-24 |
25 |
25 |
| SC7830C |
30" |
151,591 |
CSSC21-30 |
25 |
28 |
| SC7836C |
36" |
141,841 |
CSSC21-36 |
25 |
31 |
| SC7848C |
48" |
125,000 |
CSSC21-48 |
25 |
37 |
| SC7860C |
60" |
112,904 |
CSSC21-60 |
12 |
22 |
| SC7872C |
72" |
106,100 |
CSSC21-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC78D Series Range Connectors |
- 3/4" MIP x 3/4" MIP Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- 3/4" MIP Connections Tapped 1/2" FIP
- Non-Stock Item
|
3/4" MIP 3/4" MIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812D |
12" |
196,800 |
CSSC11-12 |
25 |
19 |
| SC7818D |
18" |
179,525 |
CSSC11-18 |
25 |
21 |
| SC7824D |
24" |
164,000 |
CSSC11-24 |
25 |
25 |
| SC7830D |
30" |
151,591 |
CSSC11-30 |
25 |
28 |
| SC7836D |
36" |
141,841 |
CSSC11-36 |
25 |
31 |
| SC7848D |
48" |
125,000 |
CSSC11-48 |
25 |
37 |
| SC7860D |
60" |
112,904 |
CSSC11-60 |
12 |
22 |
| SC7872D |
72" |
106,100 |
CSSC11-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC78E Series Range Connectors |
- 3/4" FIP x 1/2" MIP Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- 1/2" MIP Connection Tapped 3/8" FIP
|
3/4" FIP 1/2" MIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812E |
12" |
196,800 |
CSSC24-12 |
25 |
19 |
| SC7818E |
18" |
179,525 |
CSSC24-18 |
25 |
21 |
| SC7824E |
24" |
164,000 |
CSSC24-24 |
25 |
25 |
| SC7830E |
30" |
151,591 |
CSSC24-30 |
25 |
28 |
| SC7836E |
36" |
141,841 |
CSSC24-36 |
25 |
31 |
| SC7848E |
48" |
125,000 |
CSSC24-48 |
25 |
37 |
| SC7860E |
60" |
112,904 |
CSSC24-60 |
12 |
22 |
| SC7872E |
72" |
106,100 |
CSSC24-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC78F Series Range Connectors |
- 1/2" FIP x 1/2" FIP Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
|
1/2" FIP 1/2" FIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812F |
12" |
196,800 |
CSSC55-12 |
25 |
19 |
| SC7818F |
18" |
179,525 |
CSSC55-18 |
25 |
21 |
| SC7824F |
24" |
164,000 |
CSSC55-24 |
25 |
25 |
| SC7830F |
30" |
151,591 |
CSSC55-30 |
25 |
28 |
| SC7836F |
36" |
141,841 |
CSSC55-36 |
25 |
31 |
| SC7848F |
48" |
125,000 |
CSSC55-48 |
25 |
37 |
| SC7860F |
60" |
112,904 |
CSSC55-60 |
12 |
22 |
| SC7872F |
72" |
106,100 |
CSSC55-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC78G Series Range Connectors |
- 1/2" FIP x 3/4" MIP Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- 3/4" MIP Connection Tapped 1/2" FIP
- Non-Stock Item
|
1/2" FIP 3/4" MIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812G |
12" |
196,800 |
CSSC15-12 |
25 |
19 |
| SC7818G |
18" |
179,525 |
CSSC15-18 |
25 |
21 |
| SC7824G |
24" |
164,000 |
CSSC15-24 |
25 |
25 |
| SC7830G |
30" |
151,591 |
CSSC15-30 |
25 |
28 |
| SC7836G |
36" |
141,841 |
CSSC15-36 |
25 |
31 |
| SC7848G |
48" |
125,000 |
CSSC15-48 |
25 |
37 |
| SC7860G |
60" |
112,904 |
CSSC15-60 |
12 |
22 |
| SC7872G |
72" |
106,100 |
CSSC15-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC78H Series Range Connectors |
- 1/2" FIP x 1/2" MIP Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- 1/2" MIP Connection Tapped 3/8" FIP
|
1/2" FIP 1/2" MIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812H |
12" |
196,800 |
CSSC54-12 |
25 |
19 |
| SC7818H |
18" |
179,525 |
CSSC54-18 |
25 |
21 |
| SC7824H |
24" |
164,000 |
CSSC54-24 |
25 |
25 |
| SC7830H |
30" |
151,591 |
CSSC54-30 |
25 |
28 |
| SC7836H |
36" |
141,841 |
CSSC54-36 |
25 |
31 |
| SC7848H |
48" |
125,000 |
CSSC54-48 |
25 |
37 |
| SC7860H |
60" |
112,904 |
CSSC54-60 |
12 |
22 |
| SC7872H |
72" |
106,100 |
CSSC54-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC78I Series Range Connectors |
- 1/2" MIP x 1/2" MIP Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- 1/2" MIP Connections Tapped 3/8" FIP
|
1/2" MIP 1/2" MIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812I |
12" |
196,800 |
CSSC44-12 |
25 |
19 |
| SC7818I |
18" |
179,525 |
CSSC44-18 |
25 |
21 |
| SC7824I |
24" |
164,000 |
CSSC44-24 |
25 |
25 |
| SC7830I |
30" |
151,591 |
CSSC44-30 |
25 |
28 |
| SC7836I |
36" |
141,841 |
CSSC44-36 |
25 |
31 |
| SC7848I |
48" |
125,000 |
CSSC44-48 |
25 |
37 |
| SC7860I |
60" |
112,904 |
CSSC44-60 |
12 |
22 |
| SC7872I |
72" |
106,100 |
CSSC44-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC78J Series Range Connectors |
- 1/2" MIP x 3/4" MIP Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- 1/2" MIP Connection Tapped 3/8" FIP
- 3/4" MIP Connection Tapped 1/2" FIP
|
1/2" MIP 3/4" MIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812J |
12" |
196,800 |
CSSC14-12 |
25 |
19 |
| SC7818J |
18" |
179,525 |
CSSC14-18 |
25 |
21 |
| SC7824J |
24" |
164,000 |
CSSC14-24 |
25 |
25 |
| SC7830J |
30" |
151,591 |
CSSC14-30 |
25 |
28 |
| SC7836J |
36" |
141,841 |
CSSC14-36 |
25 |
31 |
| SC7848J |
48" |
125,000 |
CSSC14-48 |
25 |
37 |
| SC7860J |
60" |
112,904 |
CSSC14-60 |
12 |
22 |
| SC7872J |
72" |
106,100 |
CSSC14-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC78L Series Range Connectors |
- 3/4" FIP x 1/2" FIP Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
- Non Stock Item
|
3/4" FIP 1/2" FIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812L |
12" |
196,800 |
CSSC25-12 |
25 |
19 |
| SC7818L |
18" |
179,525 |
CSSC25-18 |
25 |
21 |
| SC7824L |
24" |
164,000 |
CSSC25-24 |
25 |
25 |
| SC7830L |
30" |
151,591 |
CSSC25-30 |
25 |
28 |
| SC7836L |
36" |
141,841 |
CSSC25-36 |
25 |
31 |
| SC7848L |
48" |
125,000 |
CSSC25-48 |
25 |
37 |
| SC7860L |
60" |
112,904 |
CSSC25-60 |
12 |
22 |
| SC7872L |
72" |
106,100 |
CSSC25-72 |
12 |
26 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC78V1 Series Range Connectors |
- 3/4" FIP x 3/4" FIP Straight 1/4 Turn Ball Valve Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
|
3/4" FIP 3/4" FIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812V1 |
12" |
196,800 |
CSSC2J-12 |
25 |
31 |
| SC7818V1 |
18" |
179,525 |
CSSC2J-18 |
25 |
33 |
| SC7824V1 |
24" |
164,000 |
CSSC2J-24 |
25 |
37 |
| SC7830V1 |
30" |
151,591 |
CSSC2J-30 |
25 |
40 |
| SC7836V1 |
36" |
141,841 |
CSSC2J-36 |
25 |
43 |
| SC7848V1 |
48" |
125,000 |
CSSC2J-48 |
25 |
49 |
| SC7860V1 |
60" |
112,904 |
CSSC2J-60 |
12 |
26 |
| SC7872V1 |
72" |
106,100 |
CSSC2J-72 |
12 |
31 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
| Bob® SC78V2 Series Range Connectors |
- 3/4" FIP x 3/4" FIP Angle 1/4 Turn Ball Valve Connections
- 7/8" OD (1/2" ID) Corrugated Tubing with 15/16" Flare Nuts
- Advanced "Safety Yellow" Polymer Coating
|
3/4" FIP 3/4" FIP |
Part
Number |
Length |
BTU
Capacity |
Reference
Number |
Carton |
| Qty |
Weight (Lbs) |
| SC7812V2 |
12" |
196,800 |
CSSC2P-12 |
25 |
31 |
| SC7818V2 |
18" |
179,525 |
CSSC2P-18 |
25 |
33 |
| SC7824V2 |
24" |
164,000 |
CSSC2P-24 |
25 |
37 |
| SC7830V2 |
30" |
151,591 |
CSSC2P-30 |
25 |
40 |
| SC7836V2 |
36" |
141,841 |
CSSC2P-36 |
25 |
43 |
| SC7848V2 |
48" |
125,000 |
CSSC2P-48 |
25 |
49 |
| SC7860V2 |
60" |
112,904 |
CSSC2P-60 |
12 |
26 |
| SC7872V2 |
72" |
106,100 |
CSSC2P-72 |
12 |
31 |
| Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8 |
|
 |
 |
 |
 |
|
|