Site Map |
 |
TechSpecs |
 |
|
| Bob® S, SC Series |
| Stainless Steel Gas Connectors |
|

|
 CSA Listed for USA and Canada |
- For Indoor and Outdoor Installations
|
 |
| S Series: Bright Annealed Metal Finish |
 |
 |
| SC Series: Advanced "Safety Yellow" Polymer Coating |
 |
 |
| S, SC Series TechSpecs |
| Models: (xx denotes length) |
 |
| S Series |
|
SC Series |
| S78xxB |
S12xxB |
S38xxA3 |
 |
SC78xxB |
SC12xxB |
SC38xxA3 |
| S78xxC |
S12xxC |
S38xxA5 |
|
SC78xxC |
SC12xxC |
SC38xxA5 |
| S78xxD |
S12xxD |
S38xxB |
|
SC78xxD |
S1C2xxD |
SC38xxB |
| S78xxE |
S12xxE |
S38xxC |
|
SC78xxE |
SC12xxE |
SC38xxC |
| S78xxF |
S12xxL |
S38xxE |
|
SC78xxF |
SC12xxL |
SC38xxE |
| S78xxG |
S12xxV1 |
S38xxF |
|
SC78xxG |
SC12xxV1 |
SC38xxF |
| S78xxH |
|
S38xxG |
|
SC78xxH |
|
SC38xxG |
| S78xxI |
|
S38xxH |
|
SC78xxI |
|
SC38xxH |
| S78xxJ |
|
S38xxJ |
|
SC78xxJ |
|
SC38xxJ |
| S78xxL |
|
S38xxK |
|
SC78xxL |
|
SC38xxK |
| S78xxR |
|
S38xxM |
|
SC78xxR |
|
SC38xxM |
| S78xxR5 |
|
S38xxV1 |
|
SC78xxR5 |
|
SC38xxV1 |
| S78xxV1 |
|
S38xxV1D |
|
SC78xxV1 |
|
SC38xxV1D |
| S78xxV1L |
|
|
|
SC78xxV1L |
|
|
| S78xxV1M |
|
|
|
SC78xxV1M |
|
|
| S78xxV2 |
|
|
|
SC78xxV2 |
|
|
| S78xxV2L |
|
|
|
SC78xxV2L |
|
|
| S78xxV2M |
|
|
|
SC78xxV2M |
|
|
|
 |
| Lengths: |
| 12" |
18" |
24" |
30" |
| 36" |
48" |
60" |
72" |
|
 |
| Tube & Flare Connections: |
 |
| Models |
Tube
OD |
Tube
ID |
Flare
Nuts |
| S, SC 78 Series |
7/8" |
1/2" |
15/16" |
| S, SC 12 Series |
1/2" |
3/8" |
1/2" |
| S, SC 38 Series |
3/8" |
1/4" |
3/8" |
|
 |
| Application: |
- Gas Supply Connectors for Commercial and Residential Gas
Appliances not subject to frequent movement.
- Residential Kitchen Appliances, Ranges, Ovens, Broilers
- Gas Inset Fireplace Heater Appliances
- Laundry/Utility Appliances, Clothes Dryers, Water Heaters
- Manufactured Housing (Permanent Residence Mobile Homes)
- Forced Air Heating Units
- Rooftop HVAC Units
- Suitable for use with Natural, Manufactured, Mixed, Liquified-Petrolium
Gasses, and LP Gas/Air Mixtures at System Pressures Up to 1/2 PSI.
- S78 & SC78 Series Approved as "Cross Over Connector" for Manufactured Housing.
- Do Not Use for Direct Connection to Propane Cylinders or Portable BBQs.
- Do Not Use for Castered (Easily Moveable) Equipment.
- Do Not Use with Infra-red Radiant Tube Heaters.
- Do Not Use with Wood Burning Gas Fireplace Starters.
- Follow Installation and Care Instructions on Label.
|
| Design Standards: |
- CSA Listed for Indoor and Outdoor Installations
|
 |
- ANSI Z21.24-CSA/CGA 6.10
- Connectors for Gas Appliances
|
|
- ANSI Z21.75-CSA/CGA 6.27
- Connectors for Outdoor Gas Appliances and Manufactured Homes
|
|
- All Valves CSA Listed (ANSI Z21.15/CSA 9.1) 1/2 PSI
- All Valves ASME B16.44, 5G (5 PSI)
- All Valves Rated 50 PSI WOG or Higher
|
|
- "No Neck" Design for Increased Safety
- High Tensile Strength Stainless Steel for Greater Flexibility
|
|
- Assembly Certified with End Fittings/Valves Provided
|
|
|
|
|
- City of New York Approved MEA# 123-0-3-M
|
|
|
| Material: |
- Tube: High Chrome, Bright Annealed, Type 304 Austenitic Stainless Steel
Tubing
- Nuts & End Fittings: Yellow Chromate Finish 12L14 Grade Steel
- Valves: Brass Alloy Body, Stainless or Chrome Plated Ball
|
| Operating Characteristics: |
- Pressure: Standard Line Pressures up to 1/2 PSI (5" to 16" W.C.)
Maximum
- Temperature: -40°F to 150°F, Indoor or Outdoor Use
|
- BTU Flow Rate:
- Maximum connector BTU capacity as measured per ANSI Z21. 75 - Section 2.8
- BTU/HR @ 0.5 INCH W.C. PRESSURE DROP W/1000 BTU/CU.FT. GAS
|
| Models |
Length |
| 12" |
18" |
24" |
30" |
36" |
48" |
60" |
72" |
| S,SC 78 Series BTU |
196,800 |
179,525 |
164,000 |
151,591 |
141,841 |
125,000 |
112,904 |
106,100 |
| S,SC 12 Series BTU |
122,400 |
111,720 |
102,000 |
93,939 |
87,715 |
77,000 |
65,474 |
59,000 |
| S,SC 38 Series BTU |
55,080 |
50,261 |
45,900 |
42,632 |
39,909 |
35,280 |
31,435 |
29,400 |
| BTU/HR 0.2 inch water column pressure drop can be determined by multiplying
by 0.632 |
|
 |
 |
 |
 |
|
|